Mitsubishi electric air conditioner manual km09a

Replacement Mitsubishi Electric Window Wall Mounted

Please to access BDT online customer service system for resellers of Mitsubishi Electric product in New Zealand.

Apps by Mitsubishi Electric - Living Environment Systems

OUTLINES AND DIMENSIONS WIRING DIAGRAM REFRERANT SYSTEM DIAGRAM SERVICE FUNCTIONS MICROPROCESSOR CONTROL TROUBLESHOOTING DISASSEMBLY INSTRUCTIONS 45 PARTS CATALOG (OBB531) Use the specified refrerant only Never use any refrerant other than that specified. D 7 REFRERANT SYSTEM DIAGRAM MSZ-GE22VA MSZ-GE22VAD MSZ-GE25VA MSZ-GE25VAD MSZ-GE33VA MSZ-GE35VA MSZ-GE35VA2 MSZ-GE35VAD MSZ-GE42VA MSZ-GE42VAD MSZ-GE50VA MSZ-GE50VA2 MSZ-GE50VAD Unit: mm Indoor heat exchanger Indoor coil thermistor RT12 (main) Refrerant pipe ø9.52 (MSZ-GE22/25/33/35/42) ø12.7 (MSZ-GE50) (with heat insulator) Flared connection Indoor coil thermistor RT13 (sub) Room temperature thermistor RT11 Flared connection Refrerant pipe ø6.35 (with heat insulator) Refrerant flow in cooling Refrerant flow in heating MSZ-GE60VA MSZ-GE60VAD MSZ-GE71VA MSZ-GE80VA MSZ-GE80VA2 MSZ-GE80VAD MSZ-GE71VAD Refrerant pipe ø15.88 (with heat insulator) Indoor heat exchanger Indoor coil thermistor RT12 (main) Flared connection Indoor coil thermistor RT13 (sub) Room temperature thermistor RT11 Flared connection Refrerant pipe ø6.35 (MSZ-GE60) ø9.52 (MSZ-GE71/80) (with heat insulator) Refrerant flow in cooling Refrerant flow in heating 14 8 SERVICE FUNCTIONS MSZ-GE22VA MSZ-GE22VAD MSZ-GE25VA MSZ-GE25VAD MSZ-GE33VA MSZ-GE35VA MSZ-GE35VA2 MSZ-GE35VAD MSZ-GE42VA MSZ-GE42VAD MSZ-GE50VA MSZ-GE50VA2 MSZ-GE50VAD MSZ-GE60VA MSZ-GE60VAD MSZ-GE71VA MSZ-GE71VAD MSZ-GE80VA MSZ-GE80VA2 MSZ-GE80VAD 8-1. (Refer to ,3.) Set time: 3 minutes 3 seconds (It takes 3 minutes for the compressor to start operation. BOARD MODIFICATION FOR INDIVIDUAL OPERATION A maximum of 4 indoor units with wireless remote controllers can be used in a room. After modification, put back the batteries then press the RESET button. The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down. AUTO RESTART FUNCTION automatiy starts operation in the same mode just before the shutoff of the main power.

USER'S <strong>MANUAL</strong> - <strong>Mitsubishi</strong> Heavy

MSZGE25KITD MITSUBISHI ELECTRIC 2.5KW INVERTER SPLIT

SPLIT-TYPE AIR CONDITIONERS Revision E: MSZ-GE22VAD- A1 has been added. Outdoor unit service manual MUZ-GE VA Series (OBH532) MXZ-A VA Series (OB447) CONTENTS MXZ-8A140A (OC316) MXZ-B VA (OBH567) 1. We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by failure to follow the instructions. (However, it takes at least 3 minutes for the compressor to start running.) How to disable AUTO RESTART FUNCTION Turn off the main power for the unit. (Refer to ) (MSZ-GE22/25/33/35/42/50/60/71/80VA, MSZ-GE35/50/82VA2, MSZ-GE22/25/35/42/50VAD) Cut the jumper wire to JR77 on the indoor electronic control P. If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is cancelled.

Ambi Climate - Ambi Labs

Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. TIMER SHORT MODE For service, the following set time can be shortened by bridging JPG and JPS on the electronic control P. However, the starting time is shortened by bridging JPG and JPS.) 8-2. In this case, to operate each indoor unit individually by each remote controller, P. boards of remote controller must be modified according to the number of the indoor unit. Please conduct the above setting once again after the power has restored. AUTO RESTART FUNCTION When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed are memorized by the indoor electronic control P. Operation If the main power has been cut, the operation settings remain.


Mitsubishi electric air conditioner manual km09a:

Rating: 89 / 100

Overall: 88 Rates